EN-02Environmental & Occupational Noise

Sound Power ⇄ Sound Pressure

Predict sound pressure level from sound power, directivity and room absorption. Find the critical distance.

Source

dB
W = 0.01 watts acoustic
Directivity Q
m

Environment

m²
Sound pressure level
86.4dB
Direct field only
78.0dB
Room constant R
106m²
Critical distance
2.05m
Source position
Q = 2On a floor / wall - hemispheredirectivity index DI = 3.0 dB
Level vs distance
r_c 2.1 mreverberant 85.8 dB86.4 dB0.1110100406080100120Distance from source (m)L_p (dB)
Direct fieldDirect + reverberantReverberant field
§ Theory of operation

Power is the cause, pressure the effect

Sound power level L_W is a property of the source, independent of where you measure. Sound pressure level L_pdepends on distance, the source's surroundings and the room. Manufacturers declare L_W precisely so that L_pcan be predicted for any installation.

Free field

L_p = L_W + 10\,\log_{10}\!\left(Q\,/\,4\pi r^2\right)

The directivity factor Q accounts for reflecting planes close to the source: a machine standing on a hard floor radiates into a hemisphere, doubling the intensity (+3 dB). In a corner the energy is confined to one eighth of a sphere (+9 dB).

In a room: direct + reverberant field

\begin{aligned} L_p &= L_W + 10\,\log_{10}\!\left(Q/4\pi r^2 + 4/R\right) \\ R &= S\,\bar{\alpha}\,/\,(1 - \bar{\alpha}) \qquad (\text{room constant, }\mathrm{m}^2) \end{aligned}

Close to the source the direct field dominates and the level falls 6 dB per doubling of distance. Further away, the diffuse reverberant field takes over and the level becomes constant. They are equal at the critical distance:

r_c = \sqrt{Q\,R\,/\,16\pi} \approx 0.14\,\sqrt{Q\,R}

Adding absorption only helps receivers beyond r_c; a worker standing right next to a machine gains little from an acoustic ceiling. Doubling the absorption reduces the reverberant level by 3 dB.

Limitations

The diffuse-field model assumes a reasonably proportioned room with evenly distributed absorption. In long, flat or very absorbent spaces (open-plan offices, factories with low ceilings) the reverberant level keeps decaying with distance.